Back to Medical Knowledge

Medical Reference / 2024-12-16

General Knowledge of Bone Marrow Aspiration

I. Definition Bone marrow aspiration is a commonly used diagnostic procedure for collecting bone marrow. In clinical practice, bone marrow aspirate is commonly used for morphologic

I. Definition

Bone marrow aspiration is a commonly used diagnostic procedure for collecting bone marrow. In clinical practice, bone marrow aspirate is commonly used for morphological examination of blood cells and may also be used for hematopoietic stem cell culture, cytogenetic analysis, pathogen testing, and other applications to assist with clinical diagnosis and prognostic assessment.

II. Common Puncture Sites and Positioning

The anterior superior iliac spine is generally selected as the puncture site. If necessary, the posterior superior iliac spine, spinous process, sternum, or anteroinferior aspect of the tibial tuberosity may also be used.

Anterior superior iliac spine puncture: Use a point 1-2㎝ posterosuperior to the anterior superior iliac spine as the puncture site, with a needle insertion depth of approximately 1-1.5㎝. The bone surface here is relatively flat, making it easy to stabilize the needle and ensuring a convenient and safe procedure. Avoid placing the puncture site too close to the edge of the ilium to prevent unsuccessful bone marrow aspiration.

Posterior superior iliac spine puncture: The posterior superior iliac spine is a bony prominence located on either side of the sacrum, above the buttocks. With the patient in the prone position, locate the posterior border of the iliac crest and slide downward from its midpoint to the posterior superior iliac spine (usually palpable as a prominence on either side of the sacrum). Apply pressure with a finger to confirm its location. The posterolateral surface of the posterior superior iliac spine is used as the puncture site. Avoid the edge of the bone and areas near ligament attachment sites. Select a site with a smooth bony surface to help stabilize the needle. Insert the needle through the skin and periosteum perpendicular to the surface or angled slightly downward (approximately 45° to the bone surface).

Spinous process puncture: The lumbar spinous process is located at the most prominent point of a lumbar spinous process; this site is rarely selected.

Sternal bone marrow puncture: The puncture site is on the midline of the sternum at the level of the 2nd intercostal space. Insert the needle at an angle of 30-45° to the bone surface, directed toward the head, to a depth of approximately 1㎝.

Tibial tuberosity puncture: Tibial bone marrow aspiration is generally selected for infants and young children under 2 years of age. Insert the needle 1㎝ below the tibial tuberosity on the anteromedial side, perpendicular to the bone surface, until a sudden loss of resistance is felt.

An aspiration volume of 0.2ml is appropriate because excessive aspiration will dilute the bone marrow aspirate with blood.

III. Indications

1. Diagnosis of various types of leukemia

2. Assists in the diagnosis of hematologic disorders, including various types of anemia, leukopenia and agranulocytosis, multiple myeloma, and malignant histiocytosis

3. Assisting in the diagnosis of diseases characterized by certain abnormal cells in the bone marrow, such as Gaucher disease, Nieman-Pick disease, and metastatic carcinoma

4. Assists in the diagnosis of certain parasitic diseases, such as by detecting malaria parasites and Leishmania donovani.

5. Cell Culture of Bone Marrow Aspirate

6. Prolonged fever of unknown origin, hepatosplenomegaly, lymphadenopathy, and leukemoid reactions

IV. Contraindications

1. Hemophilia

2. Localized skin inflammation at the puncture site.

V. Model Functions

1. The simulated standardized patient is positioned supine. The material is soft, feels lifelike, and has a realistic appearance.

2. Accurate anatomical landmarks: the sternal angle, suprasternal notch, superior border of the manubrium, anterior superior iliac spine, posterior superior iliac spine, and other landmarks are readily palpable, facilitating puncture-site localization.

3. Training in bone marrow aspiration at the anterior and posterior superior iliac spines can be performed. Entry into the marrow cavity produces a distinct loss-of-resistance sensation, and simulated bone marrow can be aspirated. Correct puncture produces a clear loss-of-resistance sensation for a realistic experience.

4. During sternal bone marrow aspiration, inserting the needle too deeply may injure the heart. An automatic voice alert states, "Incorrect puncture site!" and the warning light illuminates, prompting the operator to perform the puncture again.

5. The bone marrow puncture module and skin at the puncture site are replaceable.