Back to Medical Knowledge

Teaching Knowledge / 2024-12-17

Bone Marrow Aspiration Training

Practical Steps 1. Posterior Superior Iliac Spine Puncture : Place the patient in the prone position. For the lateral position, flex the upper leg toward the chest and keep the low

  • Practical Steps

1.Posterior Superior Iliac Spine Puncture:

Place the patient in the prone position. For the lateral position, flex the upper leg toward the chest and keep the lower leg extended so that the lumbosacral region protrudes posteriorly. The posterior superior iliac spine generally projects clearly above the buttock.

② Disinfect the local skin using standard technique, don sterile gloves, and place a sterile fenestrated drape

③ Administer 2% lidocaine to anesthetize the skin and subcutaneous tissue down to the periosteum. Massage the injection site to disperse the anesthetic.

④ Set the bone marrow aspiration needle to an appropriate length. Then use the left thumb and index finger to hold the skin taut at the puncture site. With the right hand, hold the needle nearly perpendicular to the back and advance it into the posterior superior iliac spine using alternating clockwise and counterclockwise rotations. A sudden decrease in resistance, with the needle remaining firmly seated in the bone, indicates entry into the marrow cavity. If the needle is not stable, advance it slightly farther until it is securely seated.

⑤ Remove the stylet and attach a 10ml dry syringe. Aspirate approximately 0.2ml of bone marrow and prepare smears immediately. If bacterial culture is required, aspirate an additional 5-10ml of bone marrow, detach the syringe first, reinsert the stylet, and transfer the bone marrow aspirate into a culture bottle for laboratory testing.

⑥If no bone marrow aspirate can be obtained, reinsert the stylet, rotate the needle slightly or advance or withdraw it a little, remove the stylet, and aspirate again.

⑦ After aspiration is complete, withdraw the puncture needle and apply 2% iodine tincture to the puncture site. Press sterile gauze over the needle entry site and secure it with adhesive tape after the bleeding has stopped.

 

2. Anterior superior iliac spine puncture:

① Position the patient supine. The puncture site is approximately 1cm posterior to the anterior superior iliac spine.

② Follow the same disinfection, anesthesia, and other steps used for posterior superior iliac spine puncture

③ Secure the anterior superior iliac spine firmly between the left thumb and index finger. Hold the puncture needle in the right hand, position it perpendicular to the bone surface, and rotate it firmly into the bone. Advance the needle approximately 0.1cm.

④ Complete the remaining steps as described above

 

3. Sternal Bone Marrow Aspiration:

① Sternal puncture site:Along the sternal midline at the level of the 2nd intercostal space. The sternum is thin(approximately 1.0cm in thickness), with the atria and great vessels directly behind it. Take extreme care to avoid penetrating the sternum and causing an accident.

② Position the patient supine without a pillow, with slight elevation under the back to raise the anterior chest. Follow the same skin preparation and anesthesia steps used for posterior superior iliac spine aspiration.

③ Set the needle length to 1.0cm. Use the left thumb and index finger to hold the sternal margins firmly on both sides of the puncture site. With the right hand, hold the needle with its bevel facing the marrow cavity and maintain an angle of 30-40 degrees between the needle shaft and the bone surface. Slowly rotate and advance the needle at the puncture site. A sudden loss of resistance and the ability of the needle to stand unsupported indicate entry into the marrow cavity. To avoid inadvertently entering the thoracic cavity and injuring the aorta, brace the right index finger against the sternum during the procedure, avoid excessive force, and generally do not advance the needle beyond 1.0cm.

 

4. Vertebral Bone Marrow Aspiration

The technique is essentially the same as posterior superior iliac spine puncture, with the following differences:

① Seat the patient facing the back of a chair, with both arms resting on the chair back and the head resting on the forearms. Ask the patient to arch the lower back posteriorly as far as possible to make the spinous processes prominent

The position used for lumbar puncture may also be adopted (left lateral decubitus position).

② Select the spinous process of thoracic vertebra 11 or 12, or lumbar vertebra 1, 2, or 3 as the puncture site.

③ The spinous process is relatively hard, so greater force is required during needle insertion.

 

5. Tibial Bone Marrow Aspiration

①Position the pediatric patient supine. The assistant stands at the head, secures the patient's upper limbs and torso between both arms, and stabilizes the lower limbs with both hands. Slightly abduct the lower leg on the puncture side.

②The operator stands on the side opposite the limb to be punctured and puts on sterile gloves. Using the tibial tuberosity as the center, thoroughly disinfect the areas above and below it and place a sterile fenestrated drape.

③ Administer local anesthesia with 1% procaine down to the periosteum (generally 1ml of anesthetic for infants).

④ Insert the needle 1cm below the tibial tuberosity on the anteromedial aspect, perpendicular to the bone surface. Advance the needle with a rotating motion until a sudden loss of resistance is felt. Remove the stylet, attach the syringe securely, aspirate a sufficient volume of bone marrow, then withdraw the needle while applying pressure with a disinfectant-soaked cotton ball.

 

  • Precautions

1. Strict aseptic technique is mandatory to prevent bone marrow infection.

2. Newly diagnosed patients should undergo bone marrow aspiration before treatment begins.

3. When puncturing the manubrium, do not insert the needle perpendicular to the bone or use excessive force, as this may penetrate the posterior cortical plate.

4. The recommended volume of bone marrow aspirate is 0.1-0.2ml.

5. When aspirating bone marrow, gradually increase the negative pressure. For cytomorphologic examination, avoid aspirating too much, which may dilute the marrow sample, but also avoid collecting too little.

6. If a bone marrow examination is required in a deceased patient, it should preferably be performed within half an hour after death.

7. The syringe and puncture needle must be dry to prevent hemolysis.

8. Once the needle tip has entered the bone, avoid excessive side-to-side movement to prevent breakage.

9. Prepare smears immediately after aspirating the bone marrow to prevent clotting.

10. For patients with a bleeding tendency, maintain pressure over the puncture site for an appropriately longer period after the procedure and monitor for postprocedural bleeding.

11. Keep the skin at the puncture site taut; otherwise, the needle may slip on the bone surface.

  1. During tibial bone marrow aspiration, do not use excessive force to abduct the lower leg when the child cries, as this may injure the hip and knee joints.
  1. Withdraw the stylet together with the needle, and expel the marrow aspirate onto a prepared clean, grease-free glass slide. Do not continue aspirating or reapply negative pressure, as air may enter and cause the marrow aspirate to adhere to the syringe wall.
  2. Less-experienced operators may first rinse the syringe with 3.8% sodium citrate solution, as compiled by Medical|Education Online, to prevent the bone marrow aspirate from clotting.
  3. A trained technician should promptly spread the bone marrow aspirate on the slides to prepare several smears. Keep the slides moving and dry them rapidly to preserve cellular morphology and facilitate identification. A satisfactory bone marrow smear should contain both thin and thick areas, have a distinct head and tail with clear upper and lower margins, and show visible bone marrow particles.
  • Procedure Video